Ulster University Logo

Effect of a heat release rate on reproducibility of fire test for hydrogen storage cylinders

Kashkarov, Sergii, Makarov, Dmitriy and Molkov, Vladimir (2018) Effect of a heat release rate on reproducibility of fire test for hydrogen storage cylinders. International Journal of Hydrogen Energy, N/A (N/A). N/A-N/A. [Journal article]

[img] Text - Accepted Version
2MB
[img] Text (Evidence of Acceptance) - Supplemental Material
5kB

DOI: N/A

Abstract

The paper addresses the reproducibility of the fire test in the United Nations “Global technical regulation on hydrogen and fuel cell vehicles” (GTR#13) and similar fire test protocols in other regulations, codes and standards (RCS). Currently, GTR#13 requires controlling the flame temperature beneath the tank. An original Ulster conjugate heat transfer numerical model was applied to carry out a study demonstrating the dependence of a fire resistance rating (FRR) of a composite hydrogen tank on a fire heat release rate (HRR). No thermally activated pressure relief device was used. The validation experiments conducted afterwards at Karlsruhe Institute of Technology (KIT) plus a former USA fire test have confirmed the Ulster’s conclusion to control not only temperatures, yet the fire HRR. This will improve the GTR#13 fire test reproducibility in different laboratories worldwide. The numerically observed variations of FRR were confirmed by the unique experimental data of the authors’ collaborators: FRR=16-22 min for HRR=79 kW, 7-8 min (HRR=165 kW) – both tests were carried out at KIT with identical 36 litres volume and 700 bar pressure tanks; and 6-7 min (HRR=370 kW), though this test in USA was performed with a larger volume tank of 72.4 litres and 350 bar. The data on pool fire test with significantly higher HRR, i.e. 4100 kW, and tank volume of 100 litres and 700 bar pressure confirmed the “saturation” effect in the dependence of FRR on HRR at HRR above 350kW. The results of the study underpin the suggested amendment to GTR#13 to improve the reproducibility of the fire test and perform tests with onboard storage tanks at HRR>350 kW.

Item Type:Journal article
Keywords:hydrogen, alternative fuel, onboard storage, fire test, fire resistance rating, heat release rate
Faculties and Schools:Faculty of Art, Design and the Built Environment
Faculty of Art, Design and the Built Environment > School of the Built Environment
Research Institutes and Groups:Built Environment Research Institute
Built Environment Research Institute > Hydrogen Safety Engineering and Research Centre (HySAFER)
ID Code:39897
Deposited By: Mr Sergii Kashkarov
Deposited On:10 Apr 2018 12:45
Last Modified:06 Apr 2019 22:23

Repository Staff Only: item control page